HPYD-53D AC/DC Hipot Test Set AC 3kVA/50kV DC 3kVA/70kV

HPYD-53D AC/DC Hipot Test Set AC 3kVA/50kV DC 3kVA/70kV
BASIC INFO

HPYD-53D AC/DC Hipot Test Set AC 3kVA/50kV DC 3kVA/70kV

 

I. General information

HPYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions.

 

II. Features

l Digital display meters mounted on the panel.

l Monitoring HV side voltage, HV side current, LV side current and indicator of zero, power, working start, timing.

l Over-current protection, zero-starting protection, sound and light alarm.

l With new type time relay, time rang is wider (1S ~ 99H).

l Using the latest current relay, more accurate and reliable.

l Light weight, small size, easy to move.

 

III. Specifications

 

A.Control unit specifications

l Power: AC220V, 50Hz

l Capacity: 3kVA

l Output voltage: AC 0-250V

l Rated output current: 15A

l Rated current rectified range: 0-15A

l HV voltmeter range: 0-70kV

  Accuracy: 1.5% of the reading±1digit (F.S)

l HV ammeter range: 0-60mA  

Accuracy: 1.5% of the reading±1 digit (F.S)

l LV ammeter range: 0-15A

Accuracy: 2.0% of the reading±1 digit (F.S)

l Timing range: 1s-99h

l Weight: 17kg

l Dimension: 440mm (L)*340mm (W)*240mm (H)

 

B. Testing transformer (HV unit) specifications

l LV side voltage (Input voltage): 0-200V

l LV side current (Input current): AC 0-15A

l HV side voltage (Output voltage): AC 0-50kV, DC 0-70kV

l HV side current (Output current): AC 60mA, DC43mA

l Capacity: 3kVA

l HV side/LV side turns ratio: 250:1

l Measuring voltage: AC 0-100V

  Accuracy: 1.5% of the reading±1 digit (F.S)

l No-load current: <10%

l Impedance voltage: <10%

l Weight: 28kg

l Dimension: 265mm(L)*240mm(W)*550mm(H)

 

C. Working conditions

l Working place: No gas, steam, chemical dust and explosive and corrosive medium which will influence insulation.

l Environment temperature: -20--50

l Environment humidity: ≤85% RH (no condensing)

 

Packing List

Control Unit                                         1 piece

Dry testing transformer (HV unit)         1 set

Microammeter & connection cable      1 piece

HV Diode                                             1 piece

Power cord                                          1 piece                          

Metering cable                                    1 piece

Output cable                                       1 piece

HV cable                                            1 piece

Ground cable                                     1 piece

User's guide                                      1 copy

Factory test report                             1 copy



If you want more information, feel free to contact us.

 

Company Profile

HONOPOWER DEVELOPMENT Co., Ltd. is a professional manufacturer specialized in electrical safety testing equipment, especially high voltage testing equipment.

 

We had researched and produced and sell test equipment for over ten yearsour products have been sold well nationwide and worldwide.

 

Our test equipment can test for various kinds of products, such as SF6 Gas, GIS Systems,Transformers,Generators, Circuit Breakers, Relays, Surge Arresters, Insulators, Cables, Casings and CT/ PTs, etc.

 

Contact Us

HONOPOWER DEVELOPMENT Co., Ltd.

Email/Skype:sales06@hvhipot.com

Mobile/Whatsapp+86 13135657923

Tel+86-27-85568138

Add 10-B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China