HONOPOWER

Hotline
13871014953
email
 info@hvhipot.com

MICHELL S8000 RS High Precision SF6 GAS Chilled Mirror Hygrometer

MICHELL S8000 RS High Precision SF6 GAS Chilled Mirror Hygrometer
BASIC INFO

MICHELL S8000 RS High Precision SF6 GAS Chilled Mirror Hygrometer

 

The S8000 RS chilled mirror sensor directly measures the formation of condensation, giving long-term and unmatched, drift-free readings of dew-point and relative humidity. It offers a wide measurement range from -90 to +20°C dew point. Fully automated control of the auxiliary cooling system means that no operator intervention is required even if the measured dew point changes from one end of the range to the other.

 

Product Features

Accuracy of ±0.1°C

Precision measurement to -90°Cdp (100 ppb) with no need for additional cooling

Simple configuration and operation via touch screen interface

Sensor head optimised for fast response to low moisture levels

Compact 19" x 4U package

Lightweight at 22.4kg

Ethernet or USB connections

SD card datalogging

 

Technical Specification

Dew-Point Sensor Performance

Measurement Accuracy*

±0.1°C

Reproducibility

±0.05°C

Measurement Technology

Chilled Mirror

Measurement Range

RS80: -80 to +20°Cdp
RS90: -90 to +20°Cdp

Mirror

Gold plated copper

Temperature Measurement

4 wire Pt100, 1/10 DIN class B

Sample Flow Rate

500 to 1000 ml/min

Sample Gas Pressure

1 MPa (10 barg) max

Remote PRT

Temperature Measurement

4 wire Pt100, 1/10 DIN class B

Measurement Accuracy

±0.1°C

Cable Length

2 metres (250 metres max)

Flow Sensor

Measurement Range

0 to 1000ml/min

Optional Integrated Pressure Sensor

Measurement Range

0 to 1.6 MPa (0 to 16 bara)

Measurement Accuracy

0.25% Full Scale

Measurement Units

barg, psig, kPa, MPa

Monitor

Resolution

User selectable to 0.001°C, depending on parameter

Measurement Units

Moisture: °C dp or °F dp, % RH, g/m3, g/kg, ppmV, ppmW (SF6)
Temperature: °C or °F
Pressure: barg, psig, kPa, Mpa

Outputs

Analog: Three channels, user selectable 4-20 mA, 0-20 mA or 0-1 V
Digital:Modbus RTU over USB and optionally Modbus RTU over RS232 or RS485, or Modbus TCP over ethernet.
Alarm: Two volt-free changeover contacts, one process alarm, one fault alarm; 1 A @ 30 V DC

HMI

5.7" LCD with touchscreen, white on blue graphics

Data Logging

SD Card (512 Mb supplied) and USB interface
Supports SD Card (FAT-32) - 32 GB max. that allows 24 million logs or 560 days, logging at 2 second intervals

Environmental Conditions

5 to 30°C, max 80% RH

Power Supply

85 to 264 V AC, 47/63 Hz

Power Consumption

250 VA

Mechanical Specification

Dimensions

190 x 444 x 550mm (h x w x d)

Weight

22.4kg

Sample Gas Circuit

316 Stainless steel

Sample Gas Connections

Inlet: ¼" VCR
Outlet: ¼" Swagelok

Optional Integrated Smaple Pump

Flow rate
1.4l/min maximum

Sample gas connections

1/4" Swagelok with bypass loop

General

Calibration

5-point in-house calibration, national standards traceable as standard
UKAS accredited calibrations optional - please consult factory

* Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.


If you want more information, feel free to contact us.

 

Company Profile

HONOPOWER DEVELOPMENT Co., Ltd. is a professional manufacturer specialized in electrical safety testing equipment, especially high voltage testing equipment.

 

We had researched and produced and sell test equipment for over ten yearsour products have been sold well nationwide and worldwide.

 

Our test equipment can test for various kinds of products, such as SF6 Gas, GIS Systems,Transformers,Generators, Circuit Breakers, Relays, Surge Arresters, Insulators, Cables, Casings and CT/ PTs, etc.

 

Contact Us

HONOPOWER DEVELOPMENT Co., Ltd.

Email/Skype:sales06@hvhipot.com

Mobile/Whatsapp+86 13135657923

Tel+86-27-85568138

Add 10-B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China