HONOPOWER HP8000S SF6 Gas Leakage Detection & O2 Content Online Monitoring System for 500kV GIS
Application
Environmental Monitoring of Indoor GIS
Environmental Monitoring of Indoor SF6 Switchgear Room
SF6 high purity gas manufacturing
R&D use
Features
1. Test terminal sensor configuration is flexible, optional infrared sensor, electrochemical sensor, ultrasonic sensor. It can be selectively adapted according to different scenes and is more flexible.
The 2.10.1 inch touch color display screen is convenient for users to communicate.
3. Industrial-grade ARM motherboard, supporting excellent OS software system, making the product more reliable.
4. Intelligent judgment algorithm, which can eliminate false alarms caused by various reasons.
5. Intelligent zero drift calibration extends the service life of the sensor.
6. The human body automatic monitoring function, when the person reaches the entrance of the monitored environment, the host automatically detects the human body signal. Start the host immediately and report monitoring environmental data.
7. The alarm data and ventilation program are self-set, and the user can set the corresponding alarm data according to the regulations.
8. Anti-electromagnetic interference circuit design to ensure product reliability.
9. USB communication, serial communication, and wireless communication modules can be expanded, and host computer communication and printing functions can be realized. (Optional)
Function
◇ Monitoring and display function of oxygen content in the environment.
◇ Monitoring and display function of SF6 gas content in the environment.
◇ The temperature and humidity monitoring and display function in the environment.
◇ Hypoxia alarm function.
◇ Alarm function for SF6 gas content exceeding standard.
◇ Timing exhaust function.
◇ Forced exhaust function for hypoxia or excessive SF6 content.
◇ Manual forced exhaust function.
◇ The last exhaust air display function.
◇ Real-time display of various parameter functions.
◇ Historical data query function.
◇ Support telecontrol system telemetry and telesignal..
◇ The original daily automatic zero calibration function can automatically overcome drift and false alarms.
◇ User-adjustable inspection interval. Suspicious detection points automatically strengthen the tracking function.
◇ When an alarm occurs, the fan will be automatically turned on and the sound and light alarm will be activated.
◇ The user can adjust the alarm parameters of SF6 and O2
◇ Support RTU telemetry and telesignal function.
◇ Mass alarm data record storage function, long life design
◇ Large color screen LCD display, humanized operation interface.
◇ Only need to increase the limited cost, the detection point can be doubled to increase the detection density.
◇ Wide working power supply design 185~250VAC, anti-wave and lightning function.
◇ Human body induction, automatically start the fan or voice system
◇ The display is relatively stable, which solves the problem of data drift.
◇ You can choose to connect with the host computer to realize remote monitoring and record events and historical events.
Technical Specifications
★ Host size: 400×300×200
★ SF6 concentration detection range: 0~1500ppm
SF6 gas detection sensitivity: ±5% setting value
★ Detection range of oxygen concentration: 0~25%
Oxygen measurement accuracy: <0.5% (0.4%, O2 at 21%)
★ Hypoxia alarm threshold: 18.0% (adjustable)
★ Temperature display range: -20~99℃
★ Humidity display range: 0~99%RH
★ Detection point: configure according to the actual situation on site
★ Data recording function: automatic recording of alarm events, mass storage and automatic update.
★Alarm output: relay empty contact output, which can be connected with RTU, and also supports RS485 alarm output.
★ Support RTU remote start fan function.
★ Support technology infrared human body detection, automatically start the fan or voice prompt.
★ Fan controller:
Switch type: directly control the fan power supply;
Pulse type: connected to the fan control switch; it can be selected according to site conditions.
★ Fan starter supports multiple modes: timing start, alarm start, automatic start when there are people, remote start, manual start, etc.
★ Various forms of host: wall-mounted explosion-proof/3U/19-inch standard chassis; 10-inch touch Android-style interface.
★ Remote transmission of measurement data is supported through RS485, such as: a large LED display is installed at the door, and the measurement parameters and system operation can be immediately seen from a distance. (Need to be selected separately by the user)
If you want more information, feel free to contact us.
Company Profile
HONOPOWER DEVELOPMENT Co., Ltd. is a professional manufacturer specialized in electrical safety testing equipment, especially high voltage testing equipment.
We had researched and produced and sell test equipment for over ten years,our products have been sold well nationwide and worldwide.
Our test equipment can test for various kinds of products, such as SF6 Gas, GIS Systems,Transformers,Generators, Circuit Breakers, Relays, Surge Arresters, Insulators, Cables, Casings and CT/ PTs, etc.
Contact Us
HONOPOWER DEVELOPMENT Co., Ltd.
Email/Skype:sales06@hvhipot.com
Mobile/Whatsapp:+86 13135657923
Tel:+86-27-85568138
Add :10-B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China