HONOPOWER

Hotline
13871014953
email
 info@hvhipot.com

HPWG SF6 Gas Leakage Detecting and Measuring System

HPWG SF6 Gas Leakage Detecting and Measuring System
BASIC INFO

HPWG SF6 Gas Leakage Detecting and Measuring System


General Information

HPWG SF6 Gas Leak Detecting and Measuring Systems high precision and sensitivity detecting system, which use NDIR technology principle and pumping cycle principle. It is used to detect few SF6 gas in the pipe quantitatively and qualitatively. Based on the design principle of infrared (detecting SF6 gas wavelength 10.2-10.6μm), the SF6 detection will be accurate.

 

Application 

SF6 detection and analysis of pipe type

SF6 detection and analysis of storage container

 

Benefits 

No radiation.

No need to replace high pressure high pure argon gas regularly.

No need to approach high pressure gas.

 

No need to replace sensors regularly, cost-effective.

Stable performance, low maintenance cost. No need to make linear calibration every year.

No affect by moisture and environment pollution.

Detection sensitivity is up to 0.1ppmv and 0.05ppmv.

When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.

 

Features

3.5inch OLED display.

One screen display SF6 gas concentration, temperature and humidity, battery indication, time and pump status. 

Friendly human machine interface.

Fast measurement speed, up to10s to achieve stable data.

Only response for SF6 gas, not for other gas.

Make sure that no sensor poisoning occurs at any concentration.

Small size, easy to carry, suitable for on-site working.

Super-light aluminum with full shielding shell.

Diaphragm pump suction sampling mode to ensure the tightness of the test gas path.

 

Specification

Measuring principle

Non-dispersive infrared sensor (NDIR)

Measuring range

(double path)

0-2000ppmv (resolution 0.1)

0-50ppmv (resolution 0.01)

limit range 0-100%

Resolution

0.1ppmv and 0.01ppmv

Accuracy:

±2%F.S.

Repeatability error

≤±1%

Response time

≤10s

Recovery time

≤15s

Long time stability(span)

≤±20ppm, more than 1000hours

Long time stability(zero)

≤±20ppm, more than 1000hours

Zero shift

≤±1%(F.S/year)

Linear error

≤±1%

Storage temperature

-20 ~ +60℃

Operation temperature

-20 ~ +50℃

Working humidity

0-95% (no condensation)

Sampling mode

Diaphragm pump, flow up to 1L/min.

Working voltage

220VAC±10%, 50Hz or Battery F750/8.4V.

Air pressure

800-1150hPa

 

 

Accessories

Main Unit

1 set


 

Detector case

 

Power cable

1pc

Sensor module

4pcs

Power charge cord

1pc

 

 

Pump case

 

Pump module

4pcs

Tube knife

2pcs

Fast connector hose

9 pairs

Sealant

1pc

Filter

6pcs

 

 

Accessory case

 

Channel cable

4pcs

Pump control cable

4pcs

Hose clamp

10pcs

PP pipe(9m)

1pc

 

 

User's Guide

1 copy

Factory Test Report

1 copy